Decompiled source of SchematicUpgradeFix v1.0.1

SchematicUpgradeFix.dll

Decompiled a month ago
using System;
using System.Diagnostics;
using System.Reflection;
using System.Runtime.CompilerServices;
using System.Runtime.Versioning;
using System.Security;
using System.Security.Permissions;
using BepInEx;
using BepInEx.Core.Logging.Interpolation;
using BepInEx.Logging;
using BepInEx.Unity.IL2CPP;
using HarmonyLib;
using Il2CppInterop.Runtime.InteropTypes;
using Il2CppSystem;
using Microsoft.CodeAnalysis;
using UISystem;
using UnityEngine.InputSystem;
using WildSkies.Gameplay.Crafting;
using WildSkies.Service;
using Wildskies.UI.Panel;
using Wildskies.UI.Panel.Schematics.Upgrade;

[assembly: CompilationRelaxations(8)]
[assembly: RuntimeCompatibility(WrapNonExceptionThrows = true)]
[assembly: Debuggable(DebuggableAttribute.DebuggingModes.IgnoreSymbolStoreSequencePoints)]
[assembly: TargetFramework(".NETCoreApp,Version=v6.0", FrameworkDisplayName = ".NET 6.0")]
[assembly: AssemblyCompany("SchematicUpgradeFix")]
[assembly: AssemblyConfiguration("Release")]
[assembly: AssemblyCopyright("Nines (Natives)")]
[assembly: AssemblyFileVersion("1.0.1.0")]
[assembly: AssemblyInformationalVersion("1.0.1")]
[assembly: AssemblyProduct("SchematicUpgradeFix")]
[assembly: AssemblyTitle("SchematicUpgradeFix")]
[assembly: SecurityPermission(SecurityAction.RequestMinimum, SkipVerification = true)]
[assembly: AssemblyVersion("1.0.1.0")]
[module: UnverifiableCode]
[module: RefSafetyRules(11)]
namespace Microsoft.CodeAnalysis
{
	[CompilerGenerated]
	[Microsoft.CodeAnalysis.Embedded]
	internal sealed class EmbeddedAttribute : Attribute
	{
	}
}
namespace System.Runtime.CompilerServices
{
	[CompilerGenerated]
	[Microsoft.CodeAnalysis.Embedded]
	[AttributeUsage(AttributeTargets.Module, AllowMultiple = false, Inherited = false)]
	internal sealed class RefSafetyRulesAttribute : Attribute
	{
		public readonly int Version;

		public RefSafetyRulesAttribute(int P_0)
		{
			Version = P_0;
		}
	}
}
namespace SchematicUpgradeFix
{
	[BepInPlugin("SchematicUpgradeFix", "SchematicUpgradeFix", "1.0.1")]
	public class Plugin : BasePlugin
	{
		internal static ManualLogSource Log;

		internal static Harmony harmonyInstance;

		public override void Load()
		{
			//IL_0015: Unknown result type (might be due to invalid IL or missing references)
			//IL_001b: Expected O, but got Unknown
			Log = ((BasePlugin)this).Log;
			ManualLogSource log = Log;
			bool flag = default(bool);
			BepInExInfoLogInterpolatedStringHandler val = new BepInExInfoLogInterpolatedStringHandler(18, 1, ref flag);
			if (flag)
			{
				((BepInExLogInterpolatedStringHandler)val).AppendLiteral("Plugin ");
				((BepInExLogInterpolatedStringHandler)val).AppendFormatted<string>("SchematicUpgradeFix");
				((BepInExLogInterpolatedStringHandler)val).AppendLiteral(" is loaded!");
			}
			log.LogInfo(val);
			harmonyInstance = Harmony.CreateAndPatchAll(typeof(Plugin), (string)null);
		}

		public override bool Unload()
		{
			Harmony obj = harmonyInstance;
			if (obj != null)
			{
				obj.UnpatchSelf();
			}
			return true;
		}

		[HarmonyPatch(typeof(LevelUpRequirementsPanel), "OnEnable")]
		[HarmonyPostfix]
		public static void LevelUpRequirementsPanel_OnEnableh(LevelUpRequirementsPanel __instance)
		{
			if (__instance._currentSelectedTechSlot == null)
			{
				SchematicUpgradeResourceSlot val = (__instance._currentSelectedTechSlot = __instance._briefTechSlot);
			}
		}

		[HarmonyPatch(typeof(SchematicsUpgradePanel), "RefreshOnItemSelected")]
		[HarmonyPostfix]
		public static void SchematicsUpgradePanel_RefreshOnItemSelected(SchematicsUpgradePanel __instance, CraftableItemBlueprint currentSchematic)
		{
			__instance._levelUpRequirementsPanel._itemBlueprint = currentSchematic;
			if (Keyboard.current.ctrlKey.isPressed && __instance._upgradeRequirementsPanel.IsActive)
			{
				ProjectContextInstaller.ResolveObject<IUIService>().PanelManager.GetPanel((UIPanelType)18, Action<PanelElement>.op_Implicit((Action<PanelElement>)delegate(PanelElement panelElement)
				{
					((Il2CppObjectBase)panelElement).Cast<SchematicsPanel>().OnUpgrade(__instance._upgradeRequirementsPanel.LevelsToAdd, __instance._upgradeRequirementsPanel.CurrentXpToUse);
				}));
			}
		}
	}
	public static class MyPluginInfo
	{
		public const string PLUGIN_GUID = "SchematicUpgradeFix";

		public const string PLUGIN_NAME = "SchematicUpgradeFix";

		public const string PLUGIN_VERSION = "1.0.1";
	}
}