Please disclose if any significant portion of your mod was created using AI tools by adding the 'AI Generated' category. Failing to do so may result in the mod being removed from Thunderstore.
Decompiled source of HearthFix v1.1.0
Narolith.HearthFix.dll
Decompiled 2 months agousing System; using System.Diagnostics; using System.Reflection; using System.Runtime.CompilerServices; using System.Runtime.Versioning; using System.Security; using System.Security.Permissions; using BepInEx; using BepInEx.Logging; using HarmonyLib; using Microsoft.CodeAnalysis; [assembly: CompilationRelaxations(8)] [assembly: RuntimeCompatibility(WrapNonExceptionThrows = true)] [assembly: Debuggable(DebuggableAttribute.DebuggingModes.IgnoreSymbolStoreSequencePoints)] [assembly: TargetFramework(".NETFramework,Version=v4.8", FrameworkDisplayName = ".NET Framework 4.8")] [assembly: AssemblyCompany("Narolith.HearthFix")] [assembly: AssemblyConfiguration("Release")] [assembly: AssemblyDescription("Fixes newly placed fireplaces and wisp torches not lighting when NoSmokeSimplified is installed")] [assembly: AssemblyFileVersion("1.1.0.0")] [assembly: AssemblyInformationalVersion("1.1.0+4689178b3258a9751dfe6bf8232e196d40d13d19")] [assembly: AssemblyProduct("Narolith.HearthFix")] [assembly: AssemblyTitle("Narolith.HearthFix")] [assembly: SecurityPermission(SecurityAction.RequestMinimum, SkipVerification = true)] [assembly: AssemblyVersion("1.1.0.0")] [module: UnverifiableCode] [module: RefSafetyRules(11)] namespace Microsoft.CodeAnalysis { [CompilerGenerated] [Microsoft.CodeAnalysis.Embedded] internal sealed class EmbeddedAttribute : Attribute { } } namespace System.Runtime.CompilerServices { [CompilerGenerated] [Microsoft.CodeAnalysis.Embedded] [AttributeUsage(AttributeTargets.Class | AttributeTargets.Property | AttributeTargets.Field | AttributeTargets.Event | AttributeTargets.Parameter | AttributeTargets.ReturnValue | AttributeTargets.GenericParameter, AllowMultiple = false, Inherited = false)] internal sealed class NullableAttribute : Attribute { public readonly byte[] NullableFlags; public NullableAttribute(byte P_0) { NullableFlags = new byte[1] { P_0 }; } public NullableAttribute(byte[] P_0) { NullableFlags = P_0; } } [CompilerGenerated] [Microsoft.CodeAnalysis.Embedded] [AttributeUsage(AttributeTargets.Class | AttributeTargets.Struct | AttributeTargets.Method | AttributeTargets.Interface | AttributeTargets.Delegate, AllowMultiple = false, Inherited = false)] internal sealed class NullableContextAttribute : Attribute { public readonly byte Flag; public NullableContextAttribute(byte P_0) { Flag = P_0; } } [CompilerGenerated] [Microsoft.CodeAnalysis.Embedded] [AttributeUsage(AttributeTargets.Module, AllowMultiple = false, Inherited = false)] internal sealed class RefSafetyRulesAttribute : Attribute { public readonly int Version; public RefSafetyRulesAttribute(int P_0) { Version = P_0; } } } namespace HearthFix { [BepInPlugin("Narolith.HearthFix", "Narolith.HearthFix", "1.1.0")] [BepInDependency(/*Could not decode attribute arguments.*/)] [BepInDependency(/*Could not decode attribute arguments.*/)] [BepInDependency(/*Could not decode attribute arguments.*/)] public class Plugin : BaseUnityPlugin { [HarmonyPatch(typeof(Fireplace), "IsBurning")] [HarmonyPriority(200)] private static class FireplaceIsBurning_Fix { private static PropertyInfo? _vplusCurrentProp; private static PropertyInfo? _vplusFireSourceProp; private static MemberInfo? _vplusFireSourceEnabledMember; private static PropertyInfo? _vplusFireSourceFiresProp; private static bool _vplusReflectionAttempted; private static void Postfix(Fireplace __instance, ref bool __result) { if (__result) { return; } ZNetView nview = __instance.m_nview; if (((nview != null) ? nview.GetZDO() : null) != null) { if (__instance.m_nview.GetZDO().GetFloat("fuel", -1f) < 0f && __instance.m_startFuel > 0f) { __result = true; } else if (IsVPlusInfiniteFires()) { __result = true; } } } private static bool IsVPlusInfiniteFires() { if (!_vplusReflectionAttempted) { _vplusReflectionAttempted = true; try { Type type = null; Assembly[] assemblies = AppDomain.CurrentDomain.GetAssemblies(); for (int i = 0; i < assemblies.Length; i++) { type = assemblies[i].GetType("ValheimPlus.Configurations.Configuration"); if (type != null) { break; } } if (type == null) { Log.LogDebug((object)"[HearthFix] V+ not loaded, skipping FireSource check"); return false; } _vplusCurrentProp = type.GetProperty("Current"); object obj = _vplusCurrentProp?.GetValue(null); if (obj == null) { return false; } _vplusFireSourceProp = obj.GetType().GetProperty("FireSource"); object obj2 = _vplusFireSourceProp?.GetValue(obj); if (obj2 == null) { return false; } Type type2 = obj2.GetType(); Type type3 = type2; while (type3 != null && _vplusFireSourceEnabledMember == null) { _vplusFireSourceEnabledMember = (MemberInfo?)(((object)type3.GetProperty("enabled", BindingFlags.DeclaredOnly | BindingFlags.Instance | BindingFlags.Public)) ?? ((object)type3.GetField("enabled", BindingFlags.DeclaredOnly | BindingFlags.Instance | BindingFlags.Public))); type3 = type3.BaseType; } _vplusFireSourceFiresProp = type2.GetProperty("fires"); } catch (Exception ex) { Log.LogWarning((object)("[HearthFix] Failed to reflect V+ config: " + ex.Message)); } } try { if (_vplusCurrentProp == null || _vplusFireSourceProp == null || _vplusFireSourceFiresProp == null) { return false; } object value = _vplusCurrentProp.GetValue(null); object value2 = _vplusFireSourceProp.GetValue(value); if (_vplusFireSourceFiresProp.GetValue(value2) as bool? != true) { return false; } if (_vplusFireSourceEnabledMember is PropertyInfo propertyInfo) { object value3 = propertyInfo.GetValue(value2); return value3 is bool && (bool)value3; } if (_vplusFireSourceEnabledMember is FieldInfo fieldInfo) { object value3 = fieldInfo.GetValue(value2); return value3 is bool && (bool)value3; } return true; } catch { return false; } } } internal static ManualLogSource Log; private static Harmony? _harmony; private void Awake() { Log = ((BaseUnityPlugin)this).Logger; Log.LogInfo((object)"HearthFix v1.1.0 loading..."); _harmony = Harmony.CreateAndPatchAll(Assembly.GetExecutingAssembly(), (string)null); Log.LogInfo((object)"HearthFix loaded."); } private void OnDestroy() { Harmony? harmony = _harmony; if (harmony != null) { harmony.UnpatchSelf(); } } } public static class PluginInfo { public const string PLUGIN_GUID = "Narolith.HearthFix"; public const string PLUGIN_NAME = "Narolith.HearthFix"; public const string PLUGIN_VERSION = "1.1.0"; } }